Corelis has developed a wide range of high-performance boundary-scan controllers that are compatible with buses such as USB 2.0, PCI, PCI Express, PXI/cPCI, Ethernet, VME, and VXI. Most of Corelis' boundary-scan controllers operate up to 80MHz sustained TCK frequency. This wide choice of platforms allows greater flexibility to meet specific price and performance criteria for a given application while maintaining complete software transportability across all hardware platforms.
 

Controller Selection Matrix  

The table below lists both current and legacy JTAG controllers offered by Corelis.   Click on the controller model below to find out more about each of our JTAG Boundary-Scan Controllers.  A brief description of each controller follows. For complete information on the controllers, please refer to the detailed datasheets. 

Interface

Model

TAPs

TCK Speed  
USB 2.0 USB-1149.1/1E

1

100 MHz
USB 2.0 USB-1149.1/4E

4

100 MHz
USB 2.0 & Ethernet NetUSB-1149.1/E

4

80 MHz
USB 2.0 & Ethernet  NetUSB-1149.1/SE

8

70 MHz
PCI PCI-1149.1/Turbo

4,8 or 32 (*)

80 MHz
PCI Express PCIe-1149.1

4,8 or 32 (*)

80 MHz
PXI/cPCI CPXI-1149.1/Turbo

4,8 or 32 (*)

80 MHz

(*) - With ScanTAP intelligent pod (ScanTAP-4, ScanTAP-8, ScanTAP-32)

 

Optional Accessory Selection Matrix

Model

TAPs

TCK Speed

Interface

 
Low Voltage Adapter

1

100 MHz

ALL
ScanTAP-IsoPod

1

40 MHz

ALL
ScanTAP Relay

1

50 MHz

ScanTAP-4
ScanTAP-8
NetUSB-1149.1/E
NetUSB-1149.1/SE

 

Controller Specifications

Programmable Clock

The system-wide TCK rate for all TAP ports is programmable under software control. A wide range of TCK frequencies can be achieved by using the on-board Phase-Locked-Loop (PLL) generation circuitry. Depending on the controller, users are given the ability to select the desired TCK rate from a range of values up to 100 MHz at resolution increments of less than 2%.

Adjustable Low Voltage Outputs

The voltage level of the parallel I/O, the local TAP port, and each pod TAP is software programmable and can be set to any voltage between 1.25V and 3.3V in increments of 0.05V. The ports of the ScanTAP-4, ScanTAP-8, and ScanTAP-32 pods can also be slew rate (fast/slow) adjusted.

Scan Input Signal Delay Compensation

Automatic delay compensation is inserted within the signal paths. This feature solves the well-known problems associated with the combination of high TCK rates and remote target locations at extended distances.

Target Voltage Detection System

The controller and its remote pod include analog-to-digital converters, which can measure connected power voltages from the target. Such voltages from two distinct target levels can be measured and compared against user-defined limits. This feature can provide detailed signal voltage checks at any stage of a test plan.

Automatic Detection of UUT Power Shorts

With the target powered down, a well-regulated drive current with current limit can be momentarily applied to the target power bus. By measuring this current, the approximate load resistance can be calculated. This provides for the automatic detection of target power shorts, prior to applying power to the target unit.
 

 

                                               Manufacturers Representatives serving Mid-Atlantic States since 1991

 